Endurance Test Set Up for Sockets

As per IEC 60884, IS 1293 and BS 1363

Endurance Test Set Up for Sockets

The test bench is designed to test 3 sockets at a time as per IS where in micro controller based mechanical fixtures (pneumatically operated) are provided for endurance testing of the sockets and plugs connected to a specific load.


















General Description:

Inductive Load for carrying out Normal Operation test at rated voltage, rated current at 0.8 P.F. and Making Breaking Test at 1.25 times rated current and 1.1 times rated voltage @ 0.6 P.F. The load will be designed to test sockets at rated voltage 230V & 250V. Following ratings of sockets can be tested at a time:

Test for 6 Amp socket – 3 Nos. at a time

Test for 10 Amp socket – 3 Nos. at a time

Test for 13 Amp socket – 3 Nos. at a time

Test for 16 Amp socket – 3 Nos. At a time

Test for 20 Amp socket - 3 Nos at a time

Test for 25 Amp socket – 3 Nos at a time

Test for 32 Amp socket – 3 Nos at a time

General Features:

Custom made pneumatically operated test jigs available for loading of product

Servo controlled operation deliverable wherever necessary for fine tuning (greater accuracy)
Industrial Grade Wire Wound Resistances with enamel coating

Micro controller based operation to control electrical as well as mechanical switching using contactors and pneumatic fixtures respectively
Per phase digital volt meter, digital ammeter and digital power

Ceramic tube based insulated industrial grade resistances

Load Selection Chart will be provided for discrete values of Voltage, Current and p.f .

Rotary switches for load selection: Ensures faster and safer operation

Fabrication: M.S. Powder Coated Cabinet.

The system can be customized to provide flexible load

Inductive Load for carrying out Normal Operation test at rated voltage, rated current at 0.8 P.F. and Making Breaking Test at 1.25 times rated current and 1.1 times rated voltage @ 0.6 P.F. The load will be designed to test sockets at rated voltage 230V & 250V. Following ratings of sockets can be tested at a time:

Test for 6 Amp socket – 3 Nos. at a time

Test for 10 Amp socket – 3 Nos. at a time

Test for 13 Amp socket – 3 Nos. at a time

Test for 16 Amp socket – 3 Nos. At a time

Test for 20 Amp socket – 3 Nos at a time

Test for 25 Amp socket – 3 Nos at a time

Test for 32 Amp socket – 3 Nos at a time

Post An Enquiry

*
*
*
*

*

*

*

captcha