Endurance Test Set Up for Fan Regulators

Load p.f. typically 0.9 +/- 0.05 for a fan regulator

Motor driven electro mechanical fixture with indexing disc to mount the UUT

Variable voltage source to adjust the set voltage

 Digital Volt meter, Digital Ammeter, Digital PF meter

Contact open sensing circuit will be provided to sense the “Open Contact” and stop the test in case of contact failure

User friendly Micro controllable unit for programming 3 Nos. of steps / Angle No. of operation

Pass, Fail and Stop Display on the Micro Controller Unit

3 independent stations can be provided to test 3 samples at a time. This number ca n be extended if necessary

 

 

The test bench is specifically designed to test multiple fan regulators as per standards so as to subject fan regulators to pre-configured (user selectable) loads to pre-settable time cycles on a microcontroller based timer unit. There can be multiple stations with a central control unit. Many leading dimmer / fan regulator manufacturers use this typical bench where in 3 dimmers can be tested at a time.