Magnetic Coils

MAGNETIC COILS FOR ABNORMAL MAGNETIC INDUCTION.

Testing Jig For Abnormal Magnetic Field DC 0.2 Tesla as per Clause No. 5.6.2.3 :

The continuous (d.c.) "abnormal" magnetic induction of 0.2 Tesla +/- 5% shall be obtained at a distance of 5mm from the Surface of the pole of the electromagnet according to Appendix-F. energised with a d.c. current. The magnetic field should be applied successively the to all the surfaces of the meter. The value of the magneto motive force to be applied shall be generally 10,000 amp-turns. However, considering the non linearity of the magnetisation of the core, the amp-turns might require slight adjustment to achieve the desired out- put.

Test Jig For Abnormal Magnetic Field AC 10milli Tesla as per Clause No. 5.6.2.4 :

The alternating (a.c) magnetic induction of 10 milli tesla shall be obtained by placing the meter at various orientation in the centre of a circular coil as specified in clause 5.6.2.2 but with 2800 amp-turns, produced by a current of a same frequency as that of the voltage applied to the meter and under the most unfavorable conditions of phase & direction.

Testing Jig for Abnormal Magnetic Field AC 0.2 Tesla as per Clause No. 5.6.2.5 :

The abnormal (a.c.) magnetic induction emanating from a circular air-cored coil (O.D.: 150mm. ID : 38mm Depth: 50mm, 14 swg. 25,000 amp-turns) producing 0.2 Tesla +/- 5% in the central region of its either surface, shall be applied successively to all the surfaces of the meter and under the most unfavorable conditions of phase and direction, to determine any abnormality under its influence.