WITH SOFTWARE CALIBRATION FACILITY
To meet the challenge of energy theft, particularly, with meter
tampering, meter manufacturers have introduced highly sophisticated
Energy meters with wide range of peripheral functions. To cope
up with this technology meter manufacturers, particularly, Indian
manufacturers have to import the calibration and Testing panels
at exorbitantly high cost. Due to privatisation and globalisation
now there is additional pressure to reduce prices and provide
enhanced functionality.
SCR Elektroniks have developed a panel for calibration of Energy
Meters with SOFTWARE CALIBRATION FACILITY. This is PC based, with
latest micro controller technology for communication with METER
UNDER TEST. The Blinking Rate of `LED' on MUT, which is proportional
to the energy registered is compared with Reference standard pulses.
The meter error is calculated and the Correction factor, compatible
to the meter protocol is generated. This factor in turn is loaded
into memory of MUT. With this factor the meter is expected to
read the correct energy. Again the error is read and confirmed
that it is within the limit. The panel is available with 1,5,10,20,40,80
test station.
TECHNICAL FEATURES / SPECIFICATIONS
SEMI-AUTOMATIC TEST PANEL :
The system comprises of :-
1. Power Source with Manual Control for Meters - 1 No.
2. Error display unit with software calibration facility.
3. Arrangement to receive Pulses from Meter Under Test.
4. Fabricated panel for connecting the meters to the system.
5. SCR Make ADD ON Card.
6. Software.
7. Reference Standard Meter
1. Power Source : It is comprise of Voltage & current
source meters with following specifications :
a. Input supply - 3 phase 50 Hz, 415 V +/- 10 %.
b. Outputs - I. Voltage Source & II. Current Source.
I. Voltage Source : Adjustable 0 - 300 Volt/1KVA
with Static phase shifting arrangement to obtain 90 Deg Lead
and 90 Deg Lag with respect to current source. Facility to switch
to 70 % and 120 % of set voltage is provided for creep test.
II.Current Source : 0 - 100 Amps adjustable in steps with Switch
and fine by variac. CT Ranges are 0.5Amp,
5Amps, 25Amps, 50Amps, 100Amps.
c. The Auto / Manual Switch is provided. The
Setting of the current is through switch in Manual Mode and through
PC in Auto Mode. Servo Controlled Current Source Keeps the current
within +/- 1% of the set value. The current indication is TRUE
RMS and available on controller itself. In terms of % of the CT
Range.
d. Digital Voltmeter 3 & 1/2 digit 0 - 300
V class 1.
e. Power Factor Meter to read PF. between 0.10
Lag - Unity - 0.10 Lead.
f. Line frequency Indicator 40 Hz to 55 Hz.
g. Outputs are provided on Insulated terminals
of proper sizes.
2. Error Display Unit : It is Micro Controller
based 6 digit display unit to indicate +/- 100 % error (-100.00
to +100.00). It will take data from Computer, Pulse Inputs from
standard meter and LED input from MUT. It also provides indication
of PASS and FAIL in case the error is out of limit.
3. Pulse Input : For each Station Input
is taken from Meter Under Test
4. Fabricated Panel : Fabricated panel to house meters
display unit and arrangement to connect meters is provided. The
arrangement for connection of the meters is simple for operation.
5. ADD ON Cards : SCR Make ADD ON Cards
are provided to interface the bench to PC.
6. Software : User friendly software is
provided which enables operator to select different test parameters
and carry out the test. It also generates different reports.
7. Reference Standard Meter Radian Make : RM - 12.
|